ELECTRICAL EQUIPMENT SAFEGUARD
Comfos Protector has modern design, multi-function, suitable to almost electrical devices. Small design helps to save energy.
Automatically cut of power against voltage of higher than 250V or lower than 170V and auto-reset power when the voltage gets back to a safe ranger in order to protect the engine.
Create a 5 minutes late of output power supply to avoid the phenomenon of gas choking in the cooling coil when the power flutters.
Automatically cut of power against voltage of higher than 250V or lower than 170V and auto-reset power when the voltage gets back to a safe ranger in order to protect the engine.
Create a 5 minutes late of output power supply to avoid the phenomenon of gas choking in the cooling coil when the power flutters.
COMFOS PROTECTOR SPECIFICATION
INSTALATION GUIDE FOR MODEL CF-DP7A1 and CF-DP15A1
Turn on “ON” button, LED screen will display “COMFOS SMART PROTECTOR” then display countdown delay time. During the countdown time, press and hold “SET/QUICK START” until screen display “SET”.
Release “SET/QUICK START”, LED screen display flashing T300 (delay time default is 300s maximum), then you can change time by pressing “SET/QUICK START” button. Each press equals 1s. Press and hold, delay time will increase continuously, stop when you reached desired delay time. After 5s, protector save automatically last setting then move on high voltage cutoff setting by displaying flashing H245 (high voltage cutoff defaut is 245V).
Press “SET/QUICK START” for changing high voltage cutoff, each press equals 1V, press and hold, high voltage cutoff will increase continuously, stop when you reached desired high voltage cutoff. After 5s, protector save automatically last setting.
Then, protector will display low voltage cutoff setting with flashing L100 (low voltage cutoff defaut is 100V). Press “SET/QUICK START” for changing low voltage cutoff, each press equals 1V, press and hold, low voltage cutoff will increase continuously, stop when you reached desired low voltage cutoff. After 5s, protector save automatically last setting.
After complete setting, LED screen will display countdown timer then protector is active with all last settings. All values will be saved until the next setting.
Turn on “ON” button, LED screen will display “COMFOS SMART PROTECTOR” then display countdown delay time. During the countdown time, press and hold “SET/QUICK START” until screen display “SET”.
Release “SET/QUICK START”, LED screen display flashing T300 (delay time default is 300s maximum), then you can change time by pressing “SET/QUICK START” button. Each press equals 1s. Press and hold, delay time will increase continuously, stop when you reached desired delay time. After 5s, protector save automatically last setting then move on high voltage cutoff setting by displaying flashing H245 (high voltage cutoff defaut is 245V).
Press “SET/QUICK START” for changing high voltage cutoff, each press equals 1V, press and hold, high voltage cutoff will increase continuously, stop when you reached desired high voltage cutoff. After 5s, protector save automatically last setting.
Then, protector will display low voltage cutoff setting with flashing L100 (low voltage cutoff defaut is 100V). Press “SET/QUICK START” for changing low voltage cutoff, each press equals 1V, press and hold, low voltage cutoff will increase continuously, stop when you reached desired low voltage cutoff. After 5s, protector save automatically last setting.
After complete setting, LED screen will display countdown timer then protector is active with all last settings. All values will be saved until the next setting.